BEZPIECZNIK PRZECIWPOŻAROWY PROJOY MC4 PEFS-EL50H-6(P2)
Product code: F3E030
Manufacturer

Prices and purchasing after loginNet prices, availability and ordering are available to verified business accounts.
Downloads
Product description
The PROJOY MC4 PEFS-EL50H-6(P2) firefighter safety switch quickly and safely isolates PV power in the event of a fault or fire. It is designed for use with three strings. Firefighters may still be exposed to current in the PV array after the DC circuit between the inverter and modules has been disconnected. If they disconnect the AC supply before fighting the fire, the PEFS switch detects the loss of mains power and opens its isolator automatically after 5 seconds. Installing it near the PV modules helps protect firefighters and reduce potential damage. The switch can be used directly in PV systems and automatically recloses when AC power is restored, without user intervention.
The units incorporate the PEDS switch, described as the most widely used DC switch for PV systems worldwide. Its mechanism responds in just 5 milliseconds to extinguish the arc rapidly. Many PV inverter manufacturers regard PEDS as their preferred DC switch.
Features of the PROJOY MC4 PEFS-EL50H-6(P2) fire safety switch:
Up to 3 strings
- up to 50 A
- up to 1500 V DC
CE marking
Motor-operated switch
- solid plastic housing IP66
Prepared openings and cable entries for MC4 connectors
Built-in DC isolator with TÜV, CE, CB, SAA, UL and CCC approvals as listed in the specification.
Automatic shut-off at 70 °C
Breather valve to prevent condensation inside the enclosure.
Technical specifications for the PROJOY MC4 PEFS-EL50H-6(P2):
- string voltage: 300–1500 V DC
- current per string: 50 A
- number of strings: 3
Number of switch poles: 6
Operating voltage: 100 V to 270 V AC.
- nominal voltage: 230 V AC
- rated current: 30 mA
- starting current - average 100mA
Maximum switch-on current: 300 mA
Communication connector: 24 V DC, 300 mA maximum.
- operating temperature range: -20 °C to +50 °C
- maximum operating temperature before automatic shutdown + 70 C
- storage temperature range: -40 °C to +85 °C
- ingress protection rating: IP66
- protection class: II
- certificates - TUV, CE, CB, SAA, UL, CCC
- DC disconnection according to the standard - EN60947-1&3
- number of operations: 10000
Number of operations under load (PV1): >1500
- dimensions: 327 mm × 241 mm × 85 mm
The units incorporate the PEDS switch, described as the most widely used DC switch for PV systems worldwide. Its mechanism responds in just 5 milliseconds to extinguish the arc rapidly. Many PV inverter manufacturers regard PEDS as their preferred DC switch.
Features of the PROJOY MC4 PEFS-EL50H-6(P2) fire safety switch:
Up to 3 strings
- up to 50 A
- up to 1500 V DC
CE marking
Motor-operated switch
- solid plastic housing IP66
Prepared openings and cable entries for MC4 connectors
Built-in DC isolator with TÜV, CE, CB, SAA, UL and CCC approvals as listed in the specification.
Automatic shut-off at 70 °C
Breather valve to prevent condensation inside the enclosure.
Technical specifications for the PROJOY MC4 PEFS-EL50H-6(P2):
- string voltage: 300–1500 V DC
- current per string: 50 A
- number of strings: 3
Number of switch poles: 6
Operating voltage: 100 V to 270 V AC.
- nominal voltage: 230 V AC
- rated current: 30 mA
- starting current - average 100mA
Maximum switch-on current: 300 mA
Communication connector: 24 V DC, 300 mA maximum.
- operating temperature range: -20 °C to +50 °C
- maximum operating temperature before automatic shutdown + 70 C
- storage temperature range: -40 °C to +85 °C
- ingress protection rating: IP66
- protection class: II
- certificates - TUV, CE, CB, SAA, UL, CCC
- DC disconnection according to the standard - EN60947-1&3
- number of operations: 10000
Number of operations under load (PV1): >1500
- dimensions: 327 mm × 241 mm × 85 mm
⌄